SparkFun BMI330 Arduino Library
v1.0.0-2-gdbddb99
Arduino Library for the SparkFun Qwiic BMI330 6-DoF IMU (Bosch BMI330)
|
Significant motion detector settings. More...
#include <sfDevBMI330.h>
Public Attributes | |
| uint16_t | blockSize = 250 |
| Samples evaluated per decision, 20 ms/LSB. More... | |
| uint16_t | peakToPeakMin = 30 |
| Minimum peak-to-peak magnitude, 1.953 mg/LSB. Range 0 to 1023. More... | |
| uint8_t | mcrMin = 17 |
| Minimum mean crossings per second. Range 0 to 63. More... | |
| uint16_t | peakToPeakMax = 253 |
| Maximum peak-to-peak magnitude, 1.953 mg/LSB. Range 0 to 1023. More... | |
| uint8_t | mcrMax = 17 |
| Maximum mean crossings per second. Range 0 to 63. More... | |
Significant motion detector settings.
Significant motion looks for sustained, human-scale movement - walking across a room rather than a door slamming nearby - by measuring the peak-to-peak acceleration magnitude and the mean-crossing rate over a block of samples, and requiring both to fall inside a window. Defaults are the device's power-on values.
| uint16_t sfe_bmi330_sig_motion_config_t::blockSize = 250 |
Samples evaluated per decision, 20 ms/LSB.
| uint8_t sfe_bmi330_sig_motion_config_t::mcrMax = 17 |
Maximum mean crossings per second. Range 0 to 63.
| uint8_t sfe_bmi330_sig_motion_config_t::mcrMin = 17 |
Minimum mean crossings per second. Range 0 to 63.
| uint16_t sfe_bmi330_sig_motion_config_t::peakToPeakMax = 253 |
Maximum peak-to-peak magnitude, 1.953 mg/LSB. Range 0 to 1023.
| uint16_t sfe_bmi330_sig_motion_config_t::peakToPeakMin = 30 |
Minimum peak-to-peak magnitude, 1.953 mg/LSB. Range 0 to 1023.